The commercial systems of optical coherence tomography (OCT) are diverse and depend on different methods to detect signals from the retina. These methods include time-domain OCT, spectral-domain OCT, and swept-source OCT. Stratus optical coherence tomography commonly belongs to the time-domain category.
Retinal tomography or optical coherence tomography (OCT) is generally used to scan the retina (back of the eye) and get high-resolution cross-sectional images. This technique utilizes light waves to take precise and detailed images of the retina and detect impairments and defects.
It also helps examine the anterior and posterior parts of the eye to arrive at the right diagnosis and treatment options in later stages. This technique is similar to computed tomography and magnetic resonance imaging. People commonly seek an OCT eye scan to investigate different eye diseases, such as glaucoma.
Optical coherence tomography was first developed in 1991 at the Massachusetts Institute of Technology. However, after just 4 years of its first inception, the device was ready to get into the market, particularly after the German manufacturer Carl Zeiss acquired the device.
Optical coherence tomography devices have gone through persistent evolution, leading eventually to the creation of Stratus optical coherence tomography (Stratus OCT), which succeeded the first generations of optical coherence tomography and became a standard instrument in ophthalmology.
The demand for Stratus OCT is increasing rapidly as many studies confirmed its efficacy and many doctors have mastered its use. In fact, more than 6,000 units of Stratus optical coherence tomography machines were sold by 2006. Popular brands include Zeiss.
Doctors use Stratus OCT to accurately diagnose many diseases and obtain ocular images after dilating the eye pupils.
Glaucoma is a common eye condition in which the optic nerve is damaged as a result of high intraocular pressure. This leads to vision impairments. It mostly affects people over the age of sixty and to a lesser extent younger people.
Often, the symptoms of this condition don appear immediately. As the condition progresses, symptoms start to appear. One of the important tests to diagnose this disease is Stratus OCT.
Symptoms of glaucoma include eye redness, severe headache, squinting, eye pain, vomiting, nausea, and blurred vision. If left untreated, this may lead to vision loss. The main risk factors that increase the chances of developing glaucoma are the following:
Age-related macular degeneration can lead to complete loss of central vision. This condition is often described as a "progressive" disease and usually occurs in the elderly. However, doctors can treat some forms of age-related macular degeneration with medication and surgery.
Diabetes-related retinopathy occurs as a result of damage to the small blood vessels of the eye. This condition can lead to glaucoma and, possibly, complete vision loss, especially when the entire retina detaches from the back of the eye. Luckily, doctors can suggest a surgery called "vitrectomy" to treat this condition.
Progressive retinal atrophy is among the genetic diseases that cause a gradual loss of vision. Most cases have choroidal membrane atrophy. In some cases, this occurs parallel to atrophy in other areas of the body, not just the eye, as is the case of some syndromes. This disease is among the rare diseases and can be diagnosed by optical coherence tomography.
Retinoblastoma is a malignant type of cancer that affects the retina. It mostly occurs in young children, and to a lesser extent in adults. The retina consists of nerve tissues that transmit light from the front part of the eye.
The signals reach the brain via the optic nerve and the brain translates them into images. Optical coherence tomography helps diagnose the tumor. The symptoms of retinoblastoma include eye swelling and redness, asymmetrical eyes, and white-colored pupil (the center of the eye).
Retinoblastoma originates from the abnormal growth of cells that make up the retina. The tumor can spread to other places in the body, such as the spine and brain. In the majority of cases, the cause of the genetic mutation that leads to the emergence of the tumor remains unclear.
Doctors could use Stratus optical coherence tomography to diagnose conditions such as cystoid macular edema, macular hole, macular pucker, and cone and cone-rod dystrophies.
Candidates who undergo refractive surgery, such as LASIK, may need to be examined by Stratus OCT. After knowing the right diagnosis, they can undergo surgery to correct longsightedness, myopia, or astigmatism, or to treat keratoconus disorder, which usually requires laser therapy to reshape the curvature of the cornea and correct the vision.
Related Article: Uveitic Macular Edema
In the early days of the OCT devices, the level of modernity and development was primitive and required more innovation. In recent times, however, the device has become more advanced as many technical changes and advancements have occurred.
The Stratus optical coherence tomography utilizes various scanning programs or protocols, such as the macular thickness map (MTM), the fast macular thickness map (FMTM), line scan, and cross-hair scan protocols. These protocols enable many features, such as:
The patient places his head in a particular chamber, and the technician adjusts the imaging device and instructs the patient to look at a target area in the device. The pictures are taken, and eye drops can be used to dilate the pupil and obtain pictures of specific areas, but usually, nothing will touch your eyes.
The examination takes only five minutes and there are no special preparation steps that you need to follow before undergoing the procedure. All you need is to focus your eyes on a green object within the machine to help the laser inside the machine to create pictures of the layers of your retina and optic nerve.
Stratus OCT technology is no more the only game in town. In fact, the new types of spectral-domain OCT devices are gaining more momentum as they provide better and faster results compared to the traditional time-domain OCT, such as Stratus OCT.
Cirrus OCT is a spectral domain OCT that can provide better image resolution with higher sensitivity and speed. This device has recently become available for purchase by many clinics around the world. What makes this device special is its ability to generate better-defined retinal images approximately 70 times faster than Stratus OCT technology. However, some studies found no significant difference between the two types.
Here are some quick general facts about optical coherence tomography:
Stratus optical coherence tomography (Stratus OCT) has become a staple technology to diagnose different eye conditions, including glaucoma and diabetes retinopathy. The features and protocols of the device make it unbeatable in terms of value and significance.
Here at International Clinics, our doctors use different kinds of optical coherence tomography devices to scan the eyes of patients and detect abnormalities that otherwise couldn be detected through other means.
Read more: Eye Surgery Preparation